Color spectrophotometer-colorimeter- glossmeter-color assessment cabinent factory.

Judge QC

This affordable, durable light booth has 5 light sources for accurate evaluation of color under controlled lighting conditions for print, packaging and industrial applications....
Two Main Shipping Way Available
Shipping Way China Post Air 10-40 days
Shipping days EMS 5-10days
Description Possible Problems

Control Lighting for Accurate Color

 

 

In manufacturing and quality control across all industries, accurate color is important. When color does not meet specifications, the result is increased cost and time to market, with more rejects and rework. That’s why it is important to view color under controlled lighting conditions. Integrating the Judge QC light booth into a color-critical workflow improves quality control and delivers a rapid ROI.

The X-Rite Judge QC is the industry’s most cost effective light booth featuring a robust industrial design. Its metal construction with a powder-coated surface is built for longevity. Its five light sources deliver consistent fluorescent illumination that complies with major international standards, including ISO, ASTM, DIN, ANSI and BSI visual assessment requirements. It has a dedicated D50 light source for print & packaging; a dedicated D65 light source for industrial applications, and a Dual Daylight mode for easy switching between light sources in situations where operators may need to view samples under both lighting conditions. The X-Rite Judge QC light booth offers an economical and effective way to judge color, anywhere color quality needs to be evaluated.

 

 

Benefits

  • Achieve better color evaluation of incoming materials with consistent lighting.
  • Benefit from robust, industrial construction that will serve you for years to come.
  • Always know exactly how functional the Judge QC lamps are with its convenient lamp service indicator.
  • Take advantage of multiple options for lamp replacement, designed to be as convenient as possible and ensure maximum up-time.
  • Check for metamerism a phenomenon that occurs when objects match in one light source but not in another.
 

The Judge QC comes fully equipped with a UVA lamp for accurate evaluation when samples contain optical brightening agents (OBAs). OBAs are used to achieve a “whiter-than-white” effect on a range of materials, including plastics, paints and coatings and paper.

 

 1. When I received NH310/NH300 colorimeter and perform measurement, why the measured data is abnormal?

After receiving NH310/NH300, you have to perform white and black calibration manually when first starting.

2. In which condition, manual white and black calibration and auto calibration  are required for NH310? 

a. It’s needed to perform manual calibration for NH310 when first starting.

b. In the subsequent starting, NH310 will perform auto calibration at startup. No need to perform manual calibration.

c.  Suggestion: it’s best to perform manual calibration once a week or when NH310 measured data is not accurate.

3. In which condition, manual white and black calibration for NH300 is required?

a. It’s needed to perform manual calibration for NH300 when first starting.

b. In the subsequent starting, no need to perform manual calibration.

c.  Suggestion: it’s best to perform manual calibration once a week or when NH300 measured data is not accurate.

4. How to replace NH310 measuring aperture?

There are three measuring apertures for NH310: Φ8mm (standard accessory), Φ4mm (standard accessory), extended Φ8mm (optional accessory)

a. Turning on

b. Removing measuring aperture, install the needed measuring aperture.

c. Select “Settings-Aperture Setting” in main menu to select corresponding measuring aperture.

d. After selecting aperture, the instrument will display “White and Black Calibration” interface. White and black calibration must be performed.

e. Replace completed.

5. CQCS3 (Color Quality Control System) Installation 

a. Before installation, please Copy CQCS3 folder to your computer and don’t remove any files in CQCS3 folder.

b. Double-click the setup.exe to install CQCS3 software.

c. Then double-click Install.bat under the CQCS3\USB_Driver file to install the driver.

d. Detailed installation information please read the "Installing Software" under CQCS3 User manual.doc.

6. How to check communication port? 

a. Connect colorimeter to the PC with USB cable.

b. Turn on the colorimeter to enter main menu. Select “Comm” and press “Enter” key to start communication.

c. Right click on “My Computer” on the desktop. Click “Manage” -> “Device Manager” -> “Ports”, you can see similar display as “SCI USB2Serial (COM6)”.

d. Click “Settings->Communication Parameters” in CQCS3 software interface. Select the corresponding port in “Serial Port”.

7. After completing CQCS3 installation, how to solve the problem if it display “! USB Device” or “! SCI USB2Serial (COM6)” when checking the communication port? 

a. Right click “! USB Device” or “! SCI USB2Serial (COM6)”, “Update Driver” -> “Install from a list or specific location (Advanced)” -> “Next” ->“Include this location in the search” -> “Browse”, specify USB driver file path “CQCS3\USB_Driver”, click “Next”. Then it will install successfully.

b.Detailed installation information please refers to “2.2 Installing USB Driver” in Color Quality Management System User Manual.doc.

8. Notes for First Using CQCS3 Software 

a. Users must specify Standard File Name, Sample File Name and Sample Database File Name when first use.

b.Standard File is use to store standard measurement data. Sample File is used to store sample measurement data. Sample Database File is used to store the measured data exported from sample records.

9. How to solve the problem when “Connection Timeout” occurred? 

a. When the colorimeter is disconnected to the PC, “Connection Timeout” will occur. At the moment, you have to check whether the USB cable is well connected the colorimeter and the PC. Then you can re-plug the USB to try out.

b. After ensuring the colorimeter is connected to the PC with USB cable, turn on the colorimeter and enter the main menu. Select “Comm” and press “Enter” key to start communication.

c. Turn off CQCS3 software, and reopen it.

10. How to solve the problem when the interface display "USB Disconnect"

a. Check whether the USB cable is connected. If not, please connect it. Check whether the connection is effective. You can re-plug the USB cable to test.

b. If the USB cable is connected well but the interface still displays "USB Disconnect", please re-start the colorimeter and enter "Menu" -"Comm"to start the communication.

c. Change the USB cable or change the USB port in you PC.

11. How to solve the problem when the colorimeter cannot be turned on in the condition of battery-powered?

a. If this phenomenon occurred, it means the battery power is not enough. You need to charge the battery.

b. When charge the battery, please insert the battery to the instrument, and plug in the adapter to charge the battery. After 5 minutes, the instrument can be turned on.  

c. If the instrument still cannot be turned on after charging 5 minutes, you can pull out the adapter and re-plug in to check it. Or repeat this operation.

d. If the instrument still cannot be turned on after charging 5 minutes, you can turn off the colorimeter and turn on it again to check it. Or repeat this operation.

e. If you have tried all the methods above but the colorimeter still cannot be turned on, please change the battery.